The new Raynger MX family of handheld, infrared thermometers takes noncontact temperature measurement into the future. Designed for ease of-use, unmatched performance, and featuring new laser technology, the MX is the professional's tool of choice.
Models and features.
The MX measures a temperature range of -30 to 900°C and features the unique 3 point true dot laser sighting with 3 laser aiming points that define the area that you are measuring. For special tasks all units are also available as Sub Zero Models with a temperature range of -50 to 500°C. The graphical display automatically charts the last ten temperature points using maximum and minimum values to establish the range.
The MX2 is the basic model, the MX4 is the high-performance model that accepts J & K thermocouples, thermistor (NTC), power input, and allows for data output.
A usefull table of 30 preset material emissivity listings is easily accessed. Simply scroll down and locate the correct material. Both the MX2 and the MX4 are available with Standard or Close Focus optics (6mm spot size at 300mm distance)
The MX4+ package includes Windows-compatible data management software, a thermocouple K probe, an RS232 computer cable, and a plug-in power supply.
Price List| Features | MX2 | MX4+ |
|---|---|---|
| MAX and MIN Temperature | ![]() |
![]() |
| DIF and AVG temperature | ![]() |
|
| Audible/visible LO-Alarm | ![]() |
|
| Audible/visible HI-Alarm | ![]() |
![]() |
| 3 spot True Dot laser sighting (Laser IEC Class 2) | ![]() |
![]() |
| Adjustable emissivity | ![]() |
![]() |
| On-board emissivity table | ![]() |
|
| Graphical display | ![]() |
![]() |
| Internal data logger (100 locations) | ![]() |
|
| Data Output: RS232 or 1mV per °C | ![]() |
|
| Windows-compatible software | ![]() |
|
| Power supply (110 or 220V) | ![]() |
|
| RS232 computer cable, 1.5m | ![]() |
|
| K thermocouple probe | ![]() |
| Specifications | Details |
|---|---|
| Temperature Range | -30...900°C(-50...500°C Sub Zero Model) |
| Accuracy | ±1% or reading or ±1°C, whichever is greater |
| Standard Model | 100...900°C: 1%; < 100°C: ±1°C;,0°C:±2°C |
| Sub Zero Model | -30...-5°C:±1.5°C;<-30°C:±2°C |
| Repeatability | ±0.5% of reading or ±1°C, whichever is greater |
| Response Time | (95%) 250ms |
| Spectral response | 8 - 14 um |
| Display Resolution | 0.1°C |
| Ambient operating range | 0...50°C (laser max. 45°C) |
| Relative Humidity | 10...95% at30°C, non condensing |
| Storage Temperature | -20...50°C (without batteries) |
| Power | 2x1.5 batteries, type R6, (AA), DC power input for MX4 and MX4+ |
| Dimensions/Weight | 200x170x50mm/480g |