Price List

Raynger MX

The new Raynger MX family of handheld, infrared thermometers takes noncontact temperature measurement into the future. Designed for ease of-use, unmatched performance, and featuring new laser technology, the MX is the professional's tool of choice.

Models and Features

The MX measures a temperature range of -30 to 900°C and features the unique 3 point true dot laser sighting with 3 laser aiming points that define the area that you are measuring. For special tasks all units are also available as Sub Zero Models with a temperature range of -50 to 500°C. The graphical display automatically charts the last ten temperature points using maximum and minimum values to establish the range.

The MX2 is the basic model, the MX4 is the high-performance model that accepts J & K thermocouples, thermistor (NTC), power input, and allows for data output.
A usefull table of 30 preset material emissivity listings is easily accessed. Simply scroll down and locate the correct material. Both the MX2 and the MX4 are available with Standard or Close Focus optics (6mm spot size at 300mm distance)
The MX4+ package includes Windows-compatible data management software, a theracouple K probe, an RS232 computer cable, and a plug-in power supply.

Features MX2 MX4+
MAX and MIN Temperature x x  
DIF and AVG temperature . x  
Audible/visible LO-Alarm . x  
Audible/visible HI-Alarm x x  

3 spot True Dot laser sighting
(Laser IEC Class 2)

x x  
Adjustable emissivity x x  
On-board emissivity table . x  
Graphical display x x  
Internal data logger (100 locations) . x  
Data Output: RS232 or 1mV per °C . x  
Windows-compatible software . x  
Power supply (110 or 220V) . x  
RS232 computer cable, 1.5m . x  
K thermocouple probe . x  

Specifications
Temperature Range -30...900°C(-50...500°C Sub Zero Model)
Accuracy +-1% or reading or +-1°C, whichever is greater
Standard Model 100...900°C: 1%; < 100°C: +-1°C;,0°C:+-2°C
Sub Zero Model -30...-5°C:+-1.5°C;<-30°C:+-2°C
Repeatability +-0.5% of reading or +-1°C, whichever is greater
Response Time (95%) 250ms
Spectral response 8 - 14 um
Display Resolution 0.1°C
Ambient operating range 0...50°C (laser max. 45°C)
Relative Humidity 10...95% at30°C, non condensing
Storage Temperature -20...50°C (without batteries)
Power 2x1.5 batteries, type R6, (AA), DC power input for MX4 and MX4+
Dimersions/Weight 200x170x50mm/480g

Product information is subject to change without notice and has been condensed for R&C Inst: customer convenience, for complete product info please Contact us or see the Raytek website.


Request Quote