The Mirage Infrared Thermometer consists of one IR Sensor, One Indicator with panel mount hardware, one 12 foot or 4 meter Interconnecting Cable, and one detailed Operations Manual.
Complete specifications and descriptions are shown in Catalog MR-05. The 20, 60, and OR Series are also available with fiber optic option. For details see Product Bulletin PB-FOMR.
The Mirage Infrared Thermometer consists of a highly reliable signal processing unit with a large and highly visible 4-digit LCD display, and choice of five high performance sensor series. Mirage infrared thermometers are ideal for applications from 150°F to 6500°F (80° to 3500°C) and feature adjustable response time of 0.01 to 10 seconds, 1% accuracy and 0.3% repeatability of full scale temperature.
- Choice of 4 Different Wavebands
- Through The Lens Viewing/Focusing
- Utilizes High Performance Temperature Detectors
- High Temperature Ratio Model (Two colour)
- Large LCD Display with PID Control
- High Optical Resolutions
- Fast Response Times
- On/Off Control Option
Specifications
Temperature sensors
- Temperature Ranges and Optical Resolution (See Catalog MR-05)
- Input Power From Indicator/Processor
- Ambient Temperature Range (without auxiliary cooling)
- 20 Series
- 0 to 200°F (-15 to 90°C)
- 30 Series
- 32 to 140°F (0 to 60°C)
- 60 Series
- 50 to 130°F (10 to 55°C)
- OR Series
- 32 to 130°F (0 to 55°C)
- Relative Humidity: 10 to 90% non-condensing
Temperature indicator/controller
- Accuracy: 1% of full scale temperature or 10°F (6°C), whichever is greater.
- Repeatability: 0.3% of full scale temperature ±1°.
- Emissivity: Control Ranges Adjustable from 0.1 to 1.0 for all series, except OR Series.
- Display: 4-digit LCD with °F or °C display.
- Out of range arrows and CAL display.
- OR Series has invalid display indication.
- On/Off control option has set-point display.
- Display updates every 1/2 second.
- OR Series E-Slope Adjustment: 0.85 to 1.15
- Invalid Alarm: LCD display indication, plus relay contact closure
- Invalid Relay Contact Rating: 1 A at 24 Vdc 0.5 A at 120 Vac-Non-inductive load
- Signal Reduction Range: Above 1500°F (800°C) will tolerate approximately 95% reduction in radiation intensity (OR Series).
- Response Time: 10 milliseconds to 10 seconds adjustable.
- Analog Outputs: 0 to 10 Vdc non-isolated (3 mA max.) isolated option available. 4 to 20 mA or 0 to 20 mA non-isolated (500 ohms load max.) isolated option available.
- Power Requirements: 100, 115, 200, 230 Vac ±10%, 50/60 Hz
- Ambient Temperature Range: 32 to 125°F (0 to 50°C) 10 to 90% R.H. non-condensing
- Construction: Meets IEC-348 and NEMA 12K standards
Options
- Peak Picker Adjustable decay rate 0.01% to 5% of span per second.
- A three-position control switch permits Off, Peaking, or Reset functions, also Reset can be activated from user supplied contact.
- Two-Point On/Off Controller
- Two Form-C relay outputs rated 3 A, 250 Vac resistive, 1 A, 250 Vac inductive.
- 30 millisecond response time (5 millisecond additional for LR Series).
- The setpoint is adjustable over the entire temperature range.
- Hysteresis: 0.3% of span or 1°F (1°C) whichever is greater
- Isolated Analog Outputs 50 Vdc maximum differential between ground and optional isolated outputs